Sign In | Join Free | My china-telecommunications.com
China Winan Industrial Limited logo
Winan Industrial Limited
Winan Industrial Limited Your Safety , My Promise
Active Member

6 Years

Home > Balanced Pressure Proportioning System >

Double Electric Ex Motors Foam Concentrate Proportioning System Maintain Equal Pressure

Winan Industrial Limited
Contact Now

Double Electric Ex Motors Foam Concentrate Proportioning System Maintain Equal Pressure

  • 1
  • 2

Brand Name : WINAN

Model Number : PHP

Certification : CCC ISO

Place of Origin : SHENZHEN, CHINA

MOQ : 1 set

Price : Negotiate

Payment Terms : T/T, L/C, Western Union

Supply Ability : 15 Set/Sets per Month

Delivery Time : Shipped in 20 days after payment

Packaging Details : Carton, Pallet, Wooden case or as required

Proportioner Size : 3"-8"

Flow : 960-15000LPM

Power Source : Electric Motor, Diesel, Hydraulic Motor

Material : 304 SS

Pump Type : Gear Pump

Package : Pallet

Contact Now

Fire Fighting Balanced Pressure Proportioning System Foam Skid

Maintain Equal Pressure , Double Electric Ex Motors Type Foam Concentrate Proportioning System


Introduction:

Balance Pressure pump skid-proportioning system accurately controls the flow of foam concentrate in to the water stream. The system automatically controls the foam concentrate over a wide range of flow and pressure, without manual adjustment.The system is typically used in the fixed foam system and specialised mobile equipments to protect tank farm, offshore platform, air craft hanger, marine dock, loading rack and in many other applications and in all types of hazard.


Parameters:

Model Size of Proportioner (mm) Working Pressure Range (MPa) Flow Range (L/S) Mixing Ratio
PHP3/24 DN65 0.6~1.2
or
0.6~1.6
6~24 3%~3.9%
or
6%~7%
PHP6/24
PHP3/42 DN100 18~42
PHP6/42
PHP3/72 18~72
PHP6/72
PHP3/100 DN150 24~100
PHP6/100
PHP3/120 24~120
PHP6/120
PHP3/160 24~160
PHP6/160
PHP3/200 DN200 48~200
PHP6/200
PHP3/260 48~260
PHP6/260
PHP3/300 DN250 75~300
PHP6/300
PHP3/400 75~400
PHP6/400



PRINCIPLE

The basic system utilizes the principle of operation based on the use of a modified venturi device called “Ratio Controller”. As the water flows through a nozzle at the inlet of ratio controller, a low-pressure area is created between the inlet nozzle and a down stream section called diffuser. This low-pressure area causes foam concentrate to flow through a metering orifice at the concentrate inlet and into the low-pressure area. As the system demand varies, the flow through the ratio controller increase or decreases, which in turn varies the pressure at low pressure area of ratio controller, creating a corresponding pressure drop across the foam concentrate metering orifice. This corresponding change of pressure results in a foam concentrate flow, which is proportional to the water flow through the ratio controller.
The pressure sensing line from the ratio controller inlet for water pressure, and from the concentrate supply side above the metering orifice are connected to a bypass valve. This valve automatically adjusts the concentrate pressure corresponding to the water pressure by re-circulating the concentrate in return line to the concentrate storage tank. Manually the pressure can also be balanced by using manual regulating globe valve to read equal pressure of the water gauge and the foam concentrate gauge (or through a duplex gauge).
The system is available as a skid mounted unit, in different flow range, varying from 150 to 18000 LPM. Each skid consist of a positive displacement pump, a pump drive, an electric control, a bypass valve, a manual regulating valve, a ratio controller, interconnecting piping in stainless steel with various controlling valves, check valve, flush-in and flush-out valve. The system is also available for operation in auto mode.

OPERATION

1. Keep wash valve closed and open all other manual valves
2. Start fire water pump to supply pressurized water for this system.
3. Press the "foam inlet valve open" button (green color) on control box to allow foam get into the system.
4. Press the "hydraulic turbine valve open" button (green color) on control box to start the hydraulic turbine. System will be under operating by now.
5. Press the "foam inlet valve close" button (red color) to stop the foam getting into the system.
6. Open the manual wash valve to allow water get into the system. Keep the fire pump running for several minutes to wash the system with fresh water.
7. Press the "hydraulic turbine valve close" button (red color) to stop the hydraulic turbine.
8. Stop fire water pump to stop water supply.
9. Close all manual valves on the skid to set it into standby condition.


Double Electric Ex Motors Foam Concentrate Proportioning System Maintain Equal Pressure

FAQ

1. Do you offer free sample for your clients?
Yes, we offer sample for most of the products.

2. What's the MOQ of your products?
Our MOQ is one (1) piece/set.

3. Are you manufacturer with your own factory?
Yes, we are the manufacturer for more than 20 years.

4. What's your payment terms?
We accept T/T, L/C, Western Union,etc.

5. How long is the delivery time?
Usually around 12 days after payment.

6. Do you have technical support?
Yes, we have a professional engineering team.

7. Do you have warranty?
Yes, all products have one year warranty.

8. Can you accept OEM?
Yes, we do customized design for our clients.




Product Tags:

foam proportioning equipment

      

skid pump units

      
Quality Double Electric Ex Motors Foam Concentrate Proportioning System Maintain Equal Pressure for sale

Double Electric Ex Motors Foam Concentrate Proportioning System Maintain Equal Pressure Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Winan Industrial Limited
*Subject:
*Message: